DRACARYS | Standard Climatic and Thermostatic Chambers

The DRACARYS Standard climatic and thermostatic chambers by Il Disgelo are stand-alone systems designed to perform controlled environmental tests involving temperature and, in climatic configurations, relative humidity, on components, materials and systems intended for industrial and research applications.

They represent the reference configuration of the DRACARYS range and combine stability, control accuracy and repeatability of test conditions, allowing programmable thermal and thermo-hygrometric cycles to be performed in a controlled and continuous manner.

The thermostatic configurations are dedicated to temperature testing, while the climatic configurations also integrate relative humidity control, making it possible to reproduce different environmental conditions according to the required test.

The chambers integrate the refrigeration system, air treatment, heating and control system within a single structure; climatic versions also include dedicated humidification and dehumidification systems.

Are designed to provide:

  • precise temperature control;
  • relative humidity control in climatic configurations;
  • high stability and uniformity of test conditions;
  • programming of thermal and thermo-hygrometric cycles;
  • management of ramps, dwell times and automatic sequences;
  • acquisition and recording of the main process parameters;
  • integration with sensors, external equipment and test benches;
  • continuous operation for qualification and validation activities;
  • dedicated configurations and accessories according to specific test requirements.

The chambers are suitable for applications in the automotive, e-mobility, electronics, aerospace, defence, battery, industrial component and research sectors, supporting development, qualification, validation and Environmental Stress Screening (ESS) activities.

The DRACARYS Standard range is available in different volumes, temperature ranges and climatic or thermostatic configurations, allowing the most suitable solution to be selected according to the dimensions of the component under test and the required environmental conditions.

  • type: stand-alone climatic and thermostatic chambers;
  • available usable volumes: from 80 L to 3500 L;
  • temperature configurations: up to −70 °C / +180 °C, depending on the model;
  • relative humidity range: up to 20% ÷ 98% RH, in climatic configurations;
  • temperature uniformity: up to ≤ 1 °C;
  • temperature resolution: up to 0.1 °C;
  • thermal gradients: defined according to the model and refrigeration configuration;
  • refrigeration system: direct, single-stage or cascade, depending on the temperature range;
  • heating: electric heaters integrated into the air-treatment system;
  • humidification: by steam generator;
  • dehumidification: by dedicated refrigeration system;
  • condensation: air-cooled, with alternative configurations available;
  • test compartment: AISI 304 stainless steel;
  • air circulation: forced ventilation;
  • control system: PLC with DOT Touch Panel and CliMaLogic®;
  • programming: climatic cycles, ramps, dwell times and automatic sequences;
  • data logging: recording of temperature, humidity and setpoints with data export;
  • connectivity: Ethernet, USB, VNC and Modbus TCP/IP;
  • power supply: 400 V ±10%, three-phase + neutral + earth;
  • remote supervision: available.

DRACARYS Standard Models

MODELTEMPERATURE RANGEVOLUME (L)EXTERNAL DIMENSIONS (mm)POWER (kW)MAX CURRENT (A)INTERNAL DIMENSIONS (mm)
CZ-UHA-80D-40 °C / +180 °C80W600 × H1390 × D13503.67.0W400 × H500 × D400
CZ-UHA-80G-70 °C / +180 °C80W600 × H1390 × D13505.010.0W400 × H500 × D400
CZ-UHA-225D-40 °C / +180 °C225W700 × H1725 × D15507.013.0W500 × H750 × D600
CZ-UHA-225G-70 °C / +180 °C225W700 × H1725 × D15508.315.0W500 × H750 × D600
CZ-UHA-408C-20 °C / +80 °C400W800 × H1825 × D17508.716.0W600 × H850 × D800
CZ-UHA-408D-40 °C / +180 °C400W800 × H1825 × D17509.417.0W600 × H850 × D800
CZ-UHA-408G-70 °C / +180 °C400W800 × H1825 × D175011.922.0W600 × H850 × D800
CZ-UHA-608D-40 °C / +180 °C600W1000 × H1925 × D17509.417.0W800 × H950 × D800
CZ-UHA-608G-70 °C / +180 °C600W1000 × H1925 × D175011.922.0W800 × H950 × D800
CZ-UHA-800D-40 °C / +180 °C1000W1200 × H1975 × D175012.924.0W1000 × H1000 × D800
CZ-UHA-800G-70 °C / +180 °C1000W1200 × H1975 × D175016.430.0W1000 × H1000 × D800
CZ-UHA-1000C-20 °C / +80 °C1000W1200 × H1975 × D195011.421.0W1000 × H1000 × D1000
CZ-UHA-1000D-40 °C / +180 °C1000W1200 × H1975 × D195012.924.0W1000 × H1000 × D1000
CZ-UHA-1000G-70 °C / +180 °C1000W1200 × H1975 × D195016.430.0W1000 × H1000 × D1000
CZ-UHA-2000C-25 °C / +100 °C2000W2200 × H1975 × D195016.530.0W2000 × H1000 × D1000
CZ-UHA-3500G-70 °C / +180 °C3500W1700 × H2500 × D32504268W1400 × H1900 × D1300

Configurable Data

The values shown represent reference technical configurations. Usable volume, temperature range, humidity control, refrigeration system, condensation system, dynamic performance, interfaces and accessories may vary depending on the selected model and the specific test requirements.

DRACARYS Standard chambers can also be configured with additional safety systems, measuring instrumentation and dedicated solutions for integration with test benches or external equipment.

ㅤㅤ

  • Measurement and data acquisition: 4 PT1000 inputs, 2 analog inputs, specimen probe and additional temperature and humidity sensors, with data acquisition and storage also from remote;
  • Interfaces and connectivity: analog and digital I/O, Modbus TCP/IP integration with SCADA, MES and LabVIEW, teleassistance and remote supervision via Ethernet;
  • Options – DRACARYS Standard
  • Measurement and monitoring:additional temperature sensors to record temperature directly on the specimen or at multiple points in the test chamber, analog inputs to acquire signals from external instruments (pressure, humidity, electrical quantities) together with the chamber data;
  • Integrated camera: to follow the specimen's behavior remotely, without opening the door or being present in the laboratory;
  • Gas analysis sampler: draws air from the test chamber and measures oxygen, hydrogen, ethylene glycol, hydrocarbons, plus R290 and R1234yf refrigerant gases with dedicated sensors, so the specimen’s emissions are detected in real time;
  • Extended climatic range: widens the temperature and relative humidity limits compared with the standard configuration, for tests under more extreme conditions;
  • Compressed-air dryer: extends control toward low dew points, for dry-air testing without condensation on the specimen;
  • Ramp-up dehumidification: on thermostatic chambers, prevents condensation on the specimen during temperature ramp-up phases;
  • Ion-exchange resin demineralizer: treats the humidifier water, limiting scaling, deposits and maintenance work;
  • Solar Testing:solar simulation lamp, for aging and radiation heat-load tests (from the 400-liter model up);
  • UVA lamps: exposure to ultraviolet rays, to assess the degradation of materials, paints and components;
  • DUT power outlet: dedicated outlet to power the specimen, which switches off automatically in the event of a chamber alarm;
  • Additional pass-through ports: from 80 to 200 mm for cables, piping and sensors, complete with silicone plug and high-temperature plastic screw cap;
  • Chamber purge with ATEX extraction fan: renews the air in the test chamber at the end of the test or on command, so the chamber can be opened safely after tests with gas or vapor emissions;
  • Safety PLC: management of safety functions with a dedicated PLC, for SIL 1 or SIL 2 systems;
  • EUCAR Hazard Levels: battery testing with classification of the EUCAR hazard level from 0 to 6, with safety and monitoring equipment suited to the expected level of the test;
  • Condensation and installation:water-cooled condensation connected to the plant water circuit, or remote air-cooled condenser installed outdoors, to avoid releasing heat and noise into the laboratory;
  • Soundproofing kit: sound-absorbing panels and anti-vibration measures, for laboratories, offices or environments with operators present;
  • Aesthetic customization: choice of RAL colors and custom writing/logos on the chamber;

ㅤ

Note

Options are defined during technical analysis, based on the DRACARYS model, usable volume, temperature and humidity range, characteristics of the component under test, heat dissipation, test method and external systems to integrate.

Request information

At your complete disposal for any information.

Please enter in the fields below, all the requested data. We will respond to your request as quickly as possible.

Request information

At your complete disposal for any information.

Please enter in the fields below, all the requested data. We will respond to your request as quickly as possible.